Temperature Data Logger Applications

installing an ultrasonic flow meter the most importantFor horizontal pipes a time of flight ultrasonic flow
consideration is the medium to be measured. Rawmeter should have the transducers fitted on the side
sewage usually requires a Doppler ultrasonic flowof the pipe. This will allow more accurate flow
meter whilst distilled or clean water requires a time ofreadings as generally air bubbles are located on the
flight ultrasonic flow meter. However, what abouttop of a pipe while sediment falls to the bottom.
applications that use a combination of liquids or liquidsDoppler transducers are generally installed on the top
with small particles? For applications where the mediaof the pipe.
has particles of 100 PPM or more a Doppler ultrasonicA typical time of flight ultrasonic flow meter will have
flow meter would be the most suitable device to use.two transducers, one will be specifically for the
For media with particles smaller than 100PPM, such asupstream direction of the flow, while the other for
oil, sea water, or even gray water a time of flightthe downstream. If you are unsure if the flow
ultrasonic flow meter types are most suitable.direction, you will normally see a negative flow rate if
A time of flight ultrasonic flow meter requires ayou have installed these incorrectly. If the
totally full pipe to work. While a typical Dopplertransducers are installed correctly and you are still
ultrasonic flow meter is more suited to a completelyhaving a problem in obtaining a correct figure from
full pipe, it is possible under certain conditions to utiliseyour ultrasonic flow meter, try different sound path
these units on partially full pipes.settings. This will require you to move your
Sensor Installationtransducers up and down the pipe as the ultrasonic
In an ideal condition a straight length of horizontalwave is reflected a different number of times on the
pipe that is at least fifteen pipe diameters long ispipe walls. Generally, the more transit paths, the more
required. This should be free of valves, inflow andaccurate your reading. However, the more transit
outflow diffusers and should be as far away frompaths can also lead to a weaker signal which can
pumps as possible. When using a time of flightcause setup difficulties; this is why it is recommended
ultrasonic flow meter on an installation that has athat you always start with the simple “V”
pump or T-section, a straight length of up to 50 pipemethod.
diameters to obtain an accurate flow reading.Take care in setting the exact liquid type, sensor
Most ultrasonic flow meter models are unable tospacing and pipe measurements. If you have
measure downward flow in a vertical pipe. The pipeincorrectly programmed any of these variables in
surface must also be clean and free from rust oryour ultrasonic flow meter you will get either an
paint bubbles. Also the ultrasonic flow meterincorrect reading, or no flow reading at all.
transducers must be clean and have a substantialOnce you have taken the time and accomplished
amount of couplant material to make a good acousticyour first ultrasonic flow meter installation, future
connection.measurements will be much easier.